  fl400 series single phase bridge rectifiers features: ? ? in-line miniature single phase silicon bridge. ? ? surge overload rating: 200 amperes peak. ? ? ideal for printed circuit board. ? ? reliable low cost construction utilizing moulded plastic technique. mechanical data: terminals : lead solderable per mil-std-202, method 208. mounting position : any. weight : 0.2 ounce, 5.6 grams. parameter FL401 fl402 fl406 units maximum recurrent peak reverse voltage 100 200 600 v maximum rms bridge input voltage 70 140 420 maximum dc blocking voltage 100 200 600 maximum average rectified output current at 50c ambient 4.0 a peak one cycle surge overload current 200 maximum forward voltage drop per bridge element at 4.0a dc 1.1 v maximum (total bridge) reverse leakage at rated dc blocking voltage 10.0 a page 1 31/05/05 v1.0 fl dimensions : inches (millimetres)
fl400 series single phase bridge rectifiers page 2 31/05/05 v1.0 rating and characteristics curves parameter FL401 fl402 fl406 units maximum (total bridge) reverse leakage at rated dc blocking voltage and 100c 1.0 ma i 2 t rating for fusing ( t <8.3ms) 93.0 a 2 seconds typical thermal resistance per leg (note 2) r ja (note 3) r jl 19.0 2.4 c/w operating temperature range -55 to +125 c storage temperature range -55 to +150 notes: 1. thermal resistance from junction to ambient with units mounted on 3.0? x 3.0? x 0.11? thick (7.5 x 7.5 x 0.3cm) aluminium pl ate. 2. thermal resistance from junction to lead with units mounted on pcb at 0.375? (9.5mm) lead length and 0.5 x 0.5? (12 x 12mm) copper pads. forward surge current, amperes pk (half sine wave) figure 1 - maximum overload surge current number of cycles at 60hz instantaneous forward current, amperes instantaneous forward voltage, volts figure 2 - typical forward characteristics (25c)
fl400 series single phase bridge rectifiers page 3 31/05/05 v1.0 v rrm (v) maximum input voltage (v ac) pin spacing current rating (a) body part number height width depth 100 70 5.1 4 15.9 19.0 6.4 FL401 200 140 fl402 600 420 fl406 specifications percent of rated peak reverse voltage figure 3 - reverse characteristics instantaneous reverse current, a forward surge current, amperes pk (half sine wave) figure 4 - non-recurrent surge rating number of cycles at 60hz dimensions : millimetres


▲Up To Search▲   

 
Price & Availability of FL401

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X